    WHAT SHOULD YOU COAT WITH FLAMEMASTIC 77
  • Cables & Pipes in vaults or channels underneath control rooms
  • Cables & Trays in Vertical Shafts
  • Cables in distribution areas
  • Hazardous areas subject to dust and vapor fires
  • Coated cables can be bent and are flexible enough to absorb movement resulting from the cyclic loading of the cables.

    FLAMEMASTIC 77 extends the operating life of power and control cables many times, when fire occurs

    FLAMEMASTIC 77 FIRE PROTECTIVE COATING
    Sprayed or painted on a group or tray of cables, FLAMEMASTIC 77 turns the group into a single "giant" cable. This seals the surface of the bundle, limiting the air which can circulate through the bundle and to the cable jackets. The lack of oxygen prevents flame development.

    FM 77 APP1

    Without air, the fuel represented by the bundle is no longer available to feed a fire.

    Even if flames should break through the layer of FLAMEMASTIC from within, the coating will prevent propagation of the fire as well as ignition of adjoining cable trays.

    EASY APPLICATION
    FLAMEMASTIC 77 is easy to apply with an airless spary gun or a paintbrush. No surface preparation other than normal dust, dirt, grease, and oil removal is necessary.

    FM 77 APP2

    ECONOMICAL
    One gallon covers approximately twelve square feet(1.11m2) or 6 linear feet of one foot wide cable tray on both sides(1.82 linear meters).

    *FLAMEMASTIC 77 does not reduce ampacity rating at recommended thickness.

    CABLE PERFORMACE COMPARISONS
    (Elapsed time before internal cable failure)
    TYPE OF CABLE UNPROTECTED FLAMEMASTIC PROTECTED
    2010 cable 0 minutes 24 minutes
    THHN cable 0 minutes 12 minutes
    XLP cable 4 minutes 21 minutes
    FREP cable 6 minutes 22 minutes
    E.P.R. /HYPALON 8 minutes 24 minutes
     

    *Factory Mutual System approved dry coating thickness is 1/16"(1.6mm)